Voltage ammeter panel mould

voltage ammeter is a can in voltage,current,power,charging
capacity,time and so on many kinds of physical measurement at the same time, also
can set parameters realize over-voltage protection, over current protection,power
protection, charging capacity protection, limited protection and voltage protection
and so on many kinds of protection function in one of the powerful measurement and
control instruments. The instrument used fluctuation two group LED digital display
tube and the test data, and can be used in flexible switch show different physical
quantities. So the meter is very suitable for need to output voltage current monitor, as
well as the battery and discharge applications.

Feature:
According to the measuring current size can choose different models
Voltage current double shows, at the same time also can switch display power,
charging capacity and time
Voltage current double shows, at the same time also can switch display power,
charging capacity and time
With P series end with output shut off function keys, flexible open or shut off
output
Very flexible online calibration function, the user may itself calibration voltage
current value
Four LED digital tube, three measured values a unit instructions
With pressure, owe pressure, flow, a power, charging and exceeds the protection
function

This series of voltage ammeter 10 optional model,The user can choose according to
different needs,pecific meaning as below:
voltage ammeter

1)VAM4020:40V20A,Don’t protect USD15.3
2)VAM9020:90V20A,Don’t protect USD16.3
3)VAM4010P:40V10A,Have protection USD16.0
4)VAM7510P:75V10A,Have protection USD17.3
5)VAM4020P:40V20A,Have protection USD17.0
6)VAM7520P:75V20A,Have protection USD20.0
7)VAM4050P:40V50A,Have protection USD25.0
8)VAM9050P:90V50A,Have protection USD25.0
9)VAM40100P:40V100A,Have protection USD29.0
10)VAM90100P:90V100A,Have protection USD29.0
voltage ammeter panel mould
voltage ammeter mould
Attention:
1)~6)for a in shape,7)~10)For his part in shape.With an expansion
board,And with standard unworthy to relay,If need can buy in part.
2. Technical index:
2.1 2 wire input voltage range: 5V~40V (4020,4050P,40100P)
8V~40V (4010P,4020P)
10V~75V (7510P,7520P)
10V~90V (9020)
3 wire input voltage range(Ext Power 12V or 24V):
0~75V (4010P ,4020P,7510P,7520P)
0~90V (4020,9020,9050P,90100P)
2.2 Output current range: 0~10A (4010P,7510P)
0~20A (4020,9020,4020P,7520P)
0~50A (4050P,9050P)
0~100A (40100P,90100P)
2.3 Voltage current show: 4 LEDs,3 Measured value + 1 display unit
2.4 Display resolution: 0.01V,0.01A,0.01W,0.01AH,0.01H
2.5 Voltage accuracy: ±1%+2 bytes
2.6 Current accuracy: ±2%+5 bytes
2.7 Measuring rate: 5 times/s
2.8 Protection type:OCP(Over-current protection),OAH(Charging protection),
OVP(Over-voltage protection),OPP(Over power protection),
OFT(Overtime protection),LOP(Voltage protection)
2.9 Protection set range: OCP Over-current protection:0.01~upper limit
OAH Charging capacity protection: 0.01AH~999AH
OVP Over-voltage protection: 0.01V~99.9V
OPP A power protection:0.01W~9.99kW(P mean W ,P. Mean kW)
OFT Overtime protection: 0.01 hours~99.9hours
2.10 Shape dimension(mm): 79*43*25
2.11. Installing hole (mm):76.5*39.2

3. Instrument structure and wiring
Figure1 The front panel
VAM panel figure1
Figure2 The behind panel
VAM panel figure2
Figure3 The behind panel
VAM panel figure3
3.1 2wire wiring:First will jump line to jump to 2 Wire state,Use 20 cm row line header
and power board,High pressure part board connection in figure4,Wiring should pay
attention to the direction.
Figure4 2wire wiring
VAM panel figure4

3.2 3wire wiring:Open the back cover,In figure 5 shows, solder welding will open,Ext
Power voltage 12V or 24V.
Figure5 3wire wiring
VAM panel figure5
3.3 General 3wire wiring:First will jump jump line 3 Wire state,Use 20 cm row line
header and power board, high pressure section connection as shown in figure 6
link,Ext power voltage 12V or 24VWiring should pay attention to the direction.
Figure6 General 3wire wiring
VAM panel figure6
3.4 3.4 Full function 3wire wiring:The connection mode and the former compared,
increased the relay,Protection function more complete,Wiring,First will jump line to
jump to 3 Wire state, use 20 cm row line header and power board, high pressure
section connection as shown in figure 7 link,Ext power voltage 12V or 24V,Wiring
should pay attention to the direction, relay power supply voltage and the choice of
external power supply voltage to match.
Figure7 3wire relay the wiring diagram

VAM panel figure7